Re: Output condition not determined when maintained output device in user record

$
0
0

Could you please share some screen shot,if possible to understand your problem in detail.

 

Few Check points-

 

  • Check Table Nast - Your billing Document should be in this table.
  • Maintain Output manually in billing document and check whether you are getting any error or not.
  • If you have configured new table for output determination ,then suggest you to go in change mode of table and double click on fields to activate table fields.
  • Have you maintain any determination requirement in your access sequence.
  • Check Transaction NACE and check what medium you have maintained 4 or 1  in your condition records.
  • Check in transaction NACE for your output type,Have you assign any program apart from RSNAST00.

 

 

Regards

 

Amit